NO. OF COND. |
SIZE (AWG) |
STRANDS |
INSULATION WALL |
4 |
10 |
7 OR 19 |
.020” PVC/.004 NYLON |
7 |
14 |
7 OR 19 |
.015” PVC/.004 NYLON |
,
Conductor: Stranded, soft annealed uncoated copper conforming to ASTM B-8.
Insulation: Polyvinyl Chloride and Nylon conforming to U.L. Style THHN/THWN for 14 AWG or larger and TFN for 16 AWG and 18 AWG.
Cable Assembly: Insulated conductors are cabled together in a suitable lay with an optional but not required 1 mil mylar tape wrapped helically over the assembly, 10% minimum overlap.
Inner Jacket: Polyvinyl chloride conforming to IPCEA S-61- 402 and NEMA WC5 - minimum average wall thickness .030”.
Color Coding:
10 AWG - Red, Black, Blue, Green/Yellow stripe.
14 AWG - Brown, White, Purple, Orange, Pink, Tan/Black Stripe, Yellow
Stripes must cover a minimum of 30% and maximum of 50% of the insulated conductor circumference and may be spirally or longitudinally applied.
Shield: .008 corrugated or flat aluminum specially coated and applied in order to bond to the outer jacket, with inner side uncoated in order to make contact with drain wire. Shield Drain: 16 AWG, 7 strand T/C drain wire inserted under shield for termination and grounding.
Outer Jacket : Black Sunlight resistant Polyethylene conforming to IPCEA S-61-402, NEMA WC5 and UL 1263. Minimum Average .050”
O.D.: .760” ± .050”.
Surface Print: Shielded Paige P7082D 10/4-14/7 Irrigation Cable 600 Volts NEC Art 675 E________________(UL) DIR BUR RoHS. Sequentially print footage every 2 ft. Manufacturing Date (DD/MM/YYYY