Products Mining CablesFLAT TUF-HIDE ARMORED SUBMERSIBLE PUMPWIRE WITH GROUND

FLAT TUF-HIDE ARMORED SUBMERSIBLE PUMPWIRE WITH GROUND

P7324AM-SP
Legacy:
Product Type

Submersible Pump Cables

Gauge Size

2 AWG & 4 AWG

Jacket

POLYVINYL CHLORIDE

Insulation

XLPE

Description
FLAT SUBMERSIBLE 3 CONDUCTOR WITH GROUND CABLE
Construction
Phase Conductor/Standard:2 AWG Soft drawn copper, ASTM B3, B496 Cross Section: 33.63mm2; 66360cmil Stranding Class: Compacted Strands: 7 x 2.585mm; 7 x 101.8mils Diameter: 6.81mm; 268cmil DC Resistance:0.523ohm/km, 0.159ohm/kft Conductor Shield: Black XLPE Thickness: 0.80mm; 31mils Diameter: 15.03mm; 592mils Insulation: Black XLPE Thickness: 3.18mm; 125mils Diameter: 15.03mm; 592mils Assembly: Paralleled Phase Conductors:3 Grounding Conductors :1 Assembly Diameter: 15.03mm, 592mils Assembly Width: 60.12mm, 2367 mils Phase Conductor/Standard: 4 AWG Cross Section: 21.153mm2; 41740cmil Stranding Class: Compacted Strands: 7 x 2.05; 7 x 80.7mils Diameter: 5.40mm; 213cmil DC Resistance: 0.831ohm/km; 0.253ohm/kft Conductor Shield: Black XLPE Thickness: 0.80mm; 125mils Diameter: 7.05mm; 278mils Insulation: Black XLPE Thickness: 3.18mm; 125mils Diameter: 13.60mm; 536mils Assembly: Paralleled Phase Conductors: 3 Grounding Conductors: 1 Assembly Diameter: 13.60mm; 538mils Assembly Width: 54.42mm; 2142mils Grounding Conductor/Standard: 6 AWG Soft drawn copper, ASTM B3, B496 Cross Section: 13.30mm2; 26240cmil Stranding Class: Compacted Strands: 7 x 1.625mm; 7 x 64.0mils Diameter: 4.28mm; 169cmil DC Resistance: 1.336ohm/km; 0.407ohm/kft Insulation: Black Green Thickness: 5.22mm; 206mils Diameter: 15.03mm; 592mils Armor: Galvanized Steel Tape Tape Thickness: 0.51mm; 20mils Overall Jacket: PVC Thickness: 2.03mm; 80mils General Data: Total Diameter: 21.3mm; 837mils Total Width: 66.3mm; 2612mils Approximate Total Weight: 2.77 Kg/m; 1.86Lb/ft Operating Temperature: 90°C; 194°F Grounding Conductor/Standard: 8 AWG Soft drawn copper, ASTM B3, B496 Cross Section: 8.37mm2; 16510cmil Stranding Class: Compacted Strands: 7 x 1.289mm; 7 x 50.7mils Diameter: 3.39mm; 133cmil DC Resistance: 2.123ohm/km; 0.647ohm/kft Insulation: Black Green Thickness: 4.95mm; 195mils Diameter: 13.60mm; 535mils Armor: Galvanized Steel Tape Tape Thickness: 0.51mm; 20mils Overall Jacket: PVC Thickness: 2.03mm; 80mils General Data: Total Diameter: 19.8mm; 781mils Total Width: 60.6mm; 2387mils Approximate Total Weight: 2.20 Kg/m; 1.48Lb/ft Operating Temperature: 90°C; 194°F
Application
5000 Volt, Submersible Pump Cable with cross-linked thermosetting polyethylene (XLPE) insulated circuit and grounding conductors, with an overall polyvinyl chloride (PVC) jacket. The cable is suitable for use within well casings for wiring deep-well submersible water pumps. Phase Conductor/Standard: 2 AWG Soft drawn copper, ASTM B3, B496 Cross Section: 33.63mm2; 66360cmil Stranding Class: Compacted Strands: 7 x 2.585mm; 7 x 101.8mils Diameter: 6.81mm; 268cmil DC Resistance: 0.523ohm/km; 0.159ohm/kft
FAQ
No FAQs available at this time.
ISO Logo

Excellence and Responsibility

Paige has earned ISO 9001:2015 certification for its factories in Columbus, NE and Silao, Mexico. We are dedicated to ensuring customer satisfaction and continual improvement, while embracing sustainability practices.

You can view our latest ISO Certificates here.