Scroll To Top

EXTRA HEAVY DUTY PORTABLE POWER CABLE – P7364M-5KV SHD-GC

Home   »   EXTRA HEAVY DUTY PORTABLE POWER CABLE – P7364M-5KV SHD-GC   »   EXTRA HEAVY DUTY PORTABLE POWER CABLE – P7364M-5KV SHD-GC

EXTRA HEAVY DUTY PORTABLE POWER CABLE – P7364M-5KV SHD-GC

Insulation

(EPR) ETHYLENE PROPYLENE RUBBER

Sizes

2 -1 AWG ICEA S-75-381/NEMA WC58, ASTM B 172, ASTM B 33, CSA C22.2 No. 96-03

Jacket

REINFORCED NEOPRENE

Temp Dry/Wet

90°C Wet/Dry, MSHA

Share it

5000V SHD-GC
PORTABLE POWER CABLE
EXTRA HEAVY DUTY
EPR / NEO 90˚C CSA MSHA MINING GRADE

  • For use as trailing mining cables.
  • Use on AC off track equipment such as longwall & continuous miners, loaders, blast hole drillers, conveyors, pumps and mobile equipment requiring grounding conductors and ground check and metallic shielding overall.
  • For use in applications where ground check conductor is required for added safety.
  • Maximum continuous conductor temperature 90°C.
  • Excellent Flexibility
  • High ozone, sun, weather and flame resistant
  • Rated and flexible at -40°C
  • Excellent impact and abrasion resistant
  • Oil and heat resistant
  • Indent printed for easy identification

Conductors:

Flexible strand tinned copper, ASTM B 172 and ASTM B33, C22.2 No. 96-03 sec4.3.1 table 3.

Seperator: Polyester tape between conductor and insulation.

Conductor Shield: Extruded semi-conducting layer over conductor. C22.2 No. 96-03.

Insulation: Ethylene-propylene rubber (EPR) C22.2 No. 96-03 see 4.3.3.

Insulation Shield:

Non-conducting bedding tape and composite tinned copper/polyamide braid 60% minimum coverage.

Color Code:

Polyamide braid color code – black, red, blue C22.2 No. 96-03 table 1.

Grounding Conductors:

Tinned copper – C22.2 No. 96-03 see 4.3.5.

Ground Check:

Yellow polypropylene-insulated tinned copper conductor, C22.2 No. 96-03 see 4.3.3/4.3.7.

Cable Assembly:

Three power conductors, ground check and two non-insulated grounding conductors cabled together to form a round cable core.

Separator: Single faced rubber-filled binder tape applied over core.

Jacket:

Black, extra heavy duty, high torsion-resistant, integral-filled, reinforced Neoprene thermoset jacket, C22.2 No. 96-03 see 4.3.9 table 2.

MSHA:

4.1.1 P-07-KA060012 (Neoprene)

4.1.2 P-7K-268101 (CPE)

4.1.3 P-07-KA030001 (TPU)

CSA:

available on request