Construction
Conductor: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8.
Insulation: Heat and moisture resistant, polyvinyl chloride meeting the requirements of UL 83 for Type THHN and THWN wires. The insulation is acceptable for use in locations at 90˚C dry or 75˚C wet. The insulation thickness is in accordance with UL 83.
Conductor Jacket: A nylon jacket is applied directly to the surface of the PVC insulation. Nylon shall meet the requirements of UL 83. The thickness is in accordance with UL 83.
Ground Conductor: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8. The conductor is insulated with PVC/Nylon and the nominal overall diameter shall equal the insulated circuit conductors.
Assembly: The insulated circuit and grounding conductors are laid flat and parallel together. The jacket will be applied directly over the insulated conductors encapsulating them.
Jacket: Heat and moisture resistant, Black polyvinyl chloride meeting the requirements of UL 83.
The thickness is in accordance with UL 83..
Color Code: Black, yellow, red & green grounding conductor
Surface Marking: The overall jacket will have the following information printed:
PAIGE SUBMERSIBLE PUMP CABLE NUMBER AND “size of conductors”, TYPE THHN/THWN 600 V (UL).
Approvals:
UL: E63611-T
MSHA: P-7K-206644