600V heavy duty SP cable w/ground – P7271-SP

Home   »   600V heavy duty SP cable w/ground – P7271-SP   »   600V heavy duty SP cable w/ground – P7271-SP
Ground THHN/PVC Flat Submersible PumpWire

600V heavy duty SP cable w/ground – P7271-SP

Voltage

600V

Insulation

PVC - Polyvinyl Chloride and Nylon

Sizes

14 AWG - 500 MCM, 2 & 3 Conductor with ground

Jacket

PVC - Polyvinyl Chloride

Share it
Approvals

3/C with Ground THHN/PVC Power & Control Submersible Pump Cable 

FLAT SUBMERSIBLE PUMP CABLE
2 & 3 CONDUCTOR W/ GROUND

Heavy Duty, (double jacketed) Flat, Submersible pump cable suitable for use within well casings  for wiring deep well fresh or salt water submersible pumps. 

Heavy duty (double jacketed), Flat Submersible pump cable suitable for use within well casings for wiring deep well fresh or salt water submersible pumps

Conductor: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8.

Insulation: Heat and moisture resistant, polyvinyl chloride meeting the requirements of UL 83 for Type THHN and THWN wires. The insulation is acceptable for use in locations at 90˚C dry or 75˚C wet. The insulation thickness is in accordance with UL 83.

Conductor Jacket: A nylon jacket is applied directly to the surface of the PVC insulation. Nylon shall meet the requirements of UL 83. The thickness is in accordance with UL 83.

Ground Conductor: Class C, soft drawn, bare copper per ASTM B3 and ASTM B8. The conductor is insulated with PVC/Nylon and the nominal overall diameter shall equal the insulated circuit conductors.

Assembly: The insulated circuit and grounding conductors are laid flat and parallel together. The jacket will be applied directly over the insulated conductors encapsulating them.

Jacket: Heat and moisture resistant, Black polyvinyl chloride meeting the requirements of UL 83.
The thickness is in accordance with UL 83..

Color Code: Black, yellow, red & green grounding conductor

Surface Marking: The overall jacket will have the following information printed:

PAIGE SUBMERSIBLE PUMP CABLE NUMBER AND “size of conductors”, TYPE THHN/THWN 600 V (UL).

Approvals:
UL: E63611-T
MSHA: P-7K-206644

PAIGE PART # NUMBER OF INSULATED CONDUCTORS CONDUCTOR SIZE GROUNDING CONDUCTOR SIZE INSULATION THICKNESS AVERAGE/MINIMUM PVC/NYLON JACKET THICKNESS CABLE O.D. CABLE WEIGHT AMPACITY(1) 40˚C
(AWG) (AWG) inches mm inches mm inches mm (LB/MFT*) AMBIENT TEMP.
020016 2 14 14 0.013/0.004 0.330/0.102 0.030 0.762 0.54 x 0.22 13.7 x 5.6 79 18
020013 2 12 12 0.037/0.004 0.939/0.102 0.030 0.762 0.56 x 0.23 14.2 x 5.8 95 24
020014 2 10 10 0.013/0.004 0.330/0.102 0.030 0.762 0.60 x 0.24 15.2 x 6.1 158 33
020012 3 14 14 0.013/0.004 0.330/0.102 0.030 0.762 0.54 x 0.22 13.7 x 5.6 110 18
020026 3 12 12 0.013/0.004 0.330/0.102 0.030 0.762 0.59 x 0.21 14.9 x 5.3 138 24
020036 3 10 10 0.013/0.004 0.330/0.102 0.045 1.143 0.75 x 0.25 190 x 6.4 210 33
020046 3 8 10 0.027/0.005 0.686/0.127 0.055 1.397 0.99 x 0.37 25.6 x 8.1 360 43
020056 3 6 8 0.027/0.005 0.686/0.127 0.060 1.524 1.18 x 0.42 29.9 x 10.6 487 58
020066 3 4 8 0.036/0.006 0.914/0.152 0.060 1.524 1.47 x 0.44 37.3 x 11.1 721 79
020076 3 2 6 0.036/0.006 0.914/0.152 0.060 1.524 1.72 x 0.50 43.6 x 12.7 1061 105
020078 3 1 6 0.045/0.007 1.143/0.178 0.060 1.524 1.915 x 0.630 48.6 x 16.0 1829 121
020086 3 1/0 6 0.045/0.007 1.143/0.178 0.060 1.524 2.170 x 0.64 55.1 x 16.2 1836 145
020096 3 2/0 6 0.045/0.007 1.143/0.178 0.060 1.524 2.360 x 0.69 59.9 x 17.5 2034 166
020106 3 3/0 6 0.045/0.007 1.143/0.178 0.060 1.524 2.580 x 0.74 65.5 x 18.7 2428 189
020116 3 4/0 4 0.045/0.007 1.143/0.178 0.060 1.524 2.820 x 0.80 71.6 x 20.3 3092 223
020126 3 250 MCM 4 0.054/0.008 1.372/0.203 0.095 2.413 3.150 x 1.00 80.0 x 25.4 4290 245
020136 3 350 MCM 3 0.054/0.008 1.372/0.203 0.095 2.413 3.550 x 1.20 90.1 x 30.4 4550 305
020146 3 500 MCM 3 0.054/0.008 1.372/0.203 0.065 1.651 3.860 x 1.065 98.0 x 27.0 8270 380
*Ampacities (Amps per conductor) are based on 30˚C ambient temperature in air