Scroll To Top

600V/2kV HYDROFLEX SP cable – P7326-SP

Home   »   600V/2kV HYDROFLEX SP cable – P7326-SP   »   600V/2kV HYDROFLEX SP cable – P7326-SP

600V/2kV HYDROFLEX SP cable – P7326-SP

Voltage

600V/2kV

Insulation

EPR - Ethylene Propylene Rubber

Sizes

#4 - 500 MCM

Jacket

CPE - Chlorinated Polyethylene Rubber

Share it
Approvals

3/C with Ground EPR/CPE, Flexible Power 
Submersible Pump Cable

FLAT SUBMERSIBLE PUMP CABLE
EXTRA FLEXIBLE HYDROFLEX
600/2000 VOLTS
3 CONDUCTOR WITH OR WITHOUT GROUND

Extra Flexible, high ampacity, Flat Rubber Submersible Pump Cable for use within well casings for wiring 
deep-well submersible water pumps, mining applications. Hydroflex is especially efficient for use in municipal 
applications, cold weather and high ampacity requirements. 

Extra Flexible, high ampacity, Flat Rubber Submersible Pump Cable for use within well casings for wiring deep-well submersible water pumps, mining applications. Hydroflex is especially efficient for use in municipal applications, cold weather, flame retardant and high ampacity requirements.

Conductors: Soft Bare, annealed copper per ASTM B-3 and ASTMB-172 Flexible, Rope-lay-stranded.

Insulation: Ethylene-propylene rubber (EPR) as per clause 7.2.4 of UL 44 plus faced rubber filled binder tape. The insulation is acceptable for use in locations at 90°C.

Ground Conductor: Soft Bare, annealed copper per ASTMB-3 and ASTMB-172 Flexible Rope-lay-stranded. Insulation EPR 90°C and the nominal overall diameter shall equal the insulated circuit conductors.

Assembly: The insulated circuit and grounding conductors are laid flat and parallel together. The jacket will be applied directly over the insulated conductors encapsulating them.

Jacket: Black Extra Heavy Duty thermosetting 90°C rated chlorinated polyethylene rubber (CPE) which meets requirements of Par. 3.21 if ICEA S-75-381 and clause 7.2.6 of UL 44. Neoprene optional jacket available.

Color Code: Black, yellow, red & green with yellow stripe grounding conductor.

Surface Marking: The overall jacket (CPE) will have the following information printed:

PAIGE ELECTRIC HYDROFLEX SUBMERSIBLE PUMP CABLE NUMBER AND SIZE (AWG) of conductors, EPR/CPE 6–/2000V 90°C (UL)

Approvals:
MSHA: P-07-KA060001-MSHA
UL: E193954

Paige Part # Conductor Size Number of Insulated Conductors Grounding Conductor Size Power Conductor Sranding Nominal Insulation Thickness Cable O.D. Cable Weight Ampacity @ 30°C Ambient Temp. *
AWG or MCM AWG No. of Stranding INCHES MM INCHES MM (LB/MFT)
070004NG 4 3 N/A 412 x 0.01 0.06 1.52 1.43 X 0.67 36.4 x 17.0 806 95
070002NG 2 3 N/A 259 x 0.0159 0.06 1.52 1.65 x 0.72 41.8 x 18.2 1209 130
070010NG 1/0 3 N/A 414 x 0.0159 0.08 2.03 1.98 x 0.87 50.4 x 22.1 1867 170
070020NG 2/0 3 N/A 522 x 0.0159 0.08 2.03 2.13 x 0.92 54.0 x 23.3 217 2 19 5
070040NG 4/0 3 N/A 829 x 0.0159 0.08 2.03 2.36 x 1.14 60.0 x 29.0 2842 260
070250NG 250 3 N/A 973 x 0.0159 0.095 2.41 2.93 x 1.33 74.6 x 33.9 3894 290
070350NG 350 3 N/A 1361 x 0.0159 0.095 2.41 3.15 x 1.41 80.0 x 35.8 5106 350
070500NG 500 3 N/A 1921 x 0.0159 0.095 2.41 3.74 x 1.56 95.1 x 39.7 6920 430
070004 4 3 6 412 x 0.01 0.06 1.52 1.83 X 0.67 46.4 x 17.0 1118 95
070002 2 3 5 259 x 0.0159 0.06 1.52 2.04 x 0.72 51.8 x 18.2 1470 130
070010 1/0 3 3 414 x 0.0159 0.08 2.03 2.54 x 0.87 64.4 x 22.1 2270 170
070020 2/0 3 2 522 x 0.0159 0.08 2.03 2.75 x 0.92 69.8 x 23.3 2710 19 5
070040 4/0 3 1/0 829 x 0.0159 0.08 2.03 3.39 x 1.14 86.0 x 29.0 3 615 260
070250 250 3 2/0 973 x 0.0159 0.095 2.41 3.92 x 1.33 99.6 x 33.9 4990 290
070350 350 3 3/0 1361 x 0.0159 0.095 2.41 4.22 x 1.41 107.2 x 35.8 6450 350
070500 500 3 250 1921 x 0.0159 0.095 2.41 4.83 x 1.56 122.8 x 39.7 8533 430