Scroll To Top

5kV – armored flat SP cable – P7324A-SP

Home   »   5kV – armored flat SP cable – P7324A-SP   »   5kV – armored flat SP cable – P7324A-SP
PUMPWIRE - Armored Flat Submersible Pump Cable

5kV – armored flat SP cable – P7324A-SP

Voltage

5000V

Insulation

XLPE

Sizes

2 & 4 AWG

Jacket

Polyvinyl Chloride

Share it
Approvals

XLPE/PVC 2 AWG & 4 AWG 3 CONDUCTOR
Submersible Pump Cable

FLAT SUBMERSIBLE
3 CONDUCTOR
WITH GROUND CABLE

5000 Volt, Submersible Pump Cable with cross-linked thermosetting polyethylene (XLPE) insulated circuit and grounding conductors, with an overall polyvinyl chloride (PVC) jacket. The cable is suitable for use within well casings for wiring deep-well submersible water pumps. 

5000 Volt, Submersible Pump Cable with cross-linked thermosetting polyethylene (XLPE) insulated circuit and grounding conductors, with an overall polyvinyl chloride (PVC) jacket. The cable is suitable for use within well casings for wiring deep-well submersible water pumps.

Phase Conductor/Standard: 2 AWG
Soft drawn copper, ASTM B3, B496
Cross Section: 33.63mm2; 66360cmil
Stranding Class: Compacted
Strands: 7 x 2.585mm; 7 x 101.8mils
Diameter: 6.81mm; 268cmil
DC Resistance: 0.523ohm/km; 0.159ohm/kft

  • Conductor Shield: Black XLPE
    Thickness: 0.80mm; 31mils
    Diameter: 15.03mm; 592mils
  • Insulation: Black XLPE
    Thickness: 3.18mm; 125mils
    Diameter: 15.03mm; 592mils
  • Assembly: Paralleled
    Phase Conductors: 3
    Grounding Conductors: 1
    Assembly Diameter: 15.03mm; 592mils
    Assembly Width: 60.12mm; 2367mils

Phase Conductor/Standard: 4 AWG
Cross Section: 21.153mm2; 41740cmil
Stranding Class: Compacted
Strands: 7 x 2.05; 7 x 80.7mils
Diameter: 5.40mm; 213cmil
DC Resistance: 0.831ohm/km; 0.253ohm/kft

  • Conductor Shield: Black XLPE
    Thickness: 0.80mm; 125mils
    Diameter: 7.05mm; 278mils
  • Insulation: Black XLPE
    Thickness: 3.18mm; 125mils
    Diameter: 13.60mm; 536mils
  • Assembly: Paralleled
    Phase Conductors: 3
    Grounding Conductors: 1
    Assembly Diameter: 13.60mm; 538mils
    Assembly Width: 54.42mm; 2142mils

Grounding Conductor/Standard: 6 AWG
Soft drawn copper, ASTM B3, B496
Cross Section: 13.30mm2; 26240cmil
Stranding Class: Compacted
Strands: 7 x 1.625mm; 7 x 64.0mils
Diameter: 4.28mm; 169cmil
DC Resistance: 1.336ohm/km; 0.407ohm/kft

  • Insulation: Black Green
    Thickness: 5.22mm; 206mils
    Diameter: 15.03mm; 592mils
  • Armor: Galvanized Steel Tape
    Tape Thickness: 0.51mm; 20mils
  • Overall Jacket: PVC
    Thickness: 2.03mm; 80mils
  • General Data:
    Total Diameter: 21.3mm; 837mils
    Total Width: 66.3mm; 2612mils
    Approximate Total Weight: 2.77 Kg/m; 1.86Lb/ft
    Operating Temperature: 90°C; 194°F

Grounding Conductor/Standard: 8 AWG
Soft drawn copper, ASTM B3, B496
Cross Section: 8.37mm2; 16510cmil
Stranding Class: Compacted
Strands: 7 x 1.289mm; 7 x 50.7mils
Diameter: 3.39mm; 133cmil
DC Resistance: 2.123ohm/km; 0.647ohm/kft

  • Insulation: Black Green
    Thickness: 4.95mm; 195mils
    Diameter: 13.60mm; 535mils
  • Armor: Galvanized Steel Tape
    Tape Thickness: 0.51mm; 20mils
  • Overall Jacket: PVC
    Thickness: 2.03mm; 80mils
  • General Data:
    Total Diameter: 19.8mm; 781mils
    Total Width: 60.6mm; 2387mils
    Approximate Total Weight: 2.20 Kg/m; 1.48Lb/ft
    Operating Temperature: 90°C; 194°F