P7324-SP 5000 Volt 3/C with Ground Tested Good for 2.4kV per NEC

5000V SP cable – P7324-SP

Voltage

5000V

Insulation

XLPE - Cross-Linked Polyethlene

Sizes

6 - 2/0 - 3 CONDUCTOR

Jacket

BLACK POLYVINYL CHLORIDE

Share it
Approvals

3/C with Ground Tested Good for 2.4kV per NEC XLPE/PVC Flat Submersible Pump Cable

Tested-Good for 2.4KV per NEC

Flat 5000v submersible pump cable with cross-linked XLPE insulated circuit and grounding conductors and an overall PVC jacket. Tested and rated for up to 2.4kV per NEC. Suitable for use within well casings for wiring deep-well submersible water pumps. 

Flat 5000V submersible pump cable with cross-linked XLPE insulated circuit and grounding conductors
and an overall PVC jacket. Tested and rated for up to 2.4kV per NEC. Suitable for use within well casings for wiring deepwell submersible water pumps

Conductors: Class B (7 strand), soft drawn, bare copper per ASTM B3 and ASTM B8.

Conductor Shield: 5 mil thick semi-conducting tape longitudinally applied over the conductor in accordance with the requirements of UL 1072.

Insulation: Heat and moisture resistant, crosslinked thermosetting polyethylene meeting the requirements of UL 1072 for 5000 Volt rated cables. The insulation thickness is in accordance with Table 13.2 of UL 1072.

Ground Conductor: Class B (7 strand), soft drawn, bare copper per ASTM B3 and ASTM B8. The conductor is fully insulated with XLPE and the nominal overall diameter shall equal the insulated circuit conductors.

Assembly: The insulated circuit conductors and one insulated grounding conductor are laid flat and parallel together. The jacket will be applied directly over the insulated conductors.

Color Code:  5KV circuit Conductors – BLACK
Grounding Conductor – GREEN

Jacket: Heat and moisture resistant, black polyvinyl chloride meeting the requirements of UL 1072. The thickness is in accordance with Table 25.15 of UL 1072.

Identification: The overall jacket will have the following information printed: PAIGE ELECTRIC FLAT PUMP CABLE “number & size of conductor” XLP 5KV “ground conductor size” GRND 90˚C WET OR DRY (UL) E#XXXXX.

Paige Part # Conductor Size Number of Conductors Grounding Conductor Size Average Insulation Thickness Jacket Thickness Nominal Cable O.D. Cable Weight
AWG AWG Ground Circuit mil Inches mm lb/mft
020506 6 3 8 131.0 125 80 2.040 x 0.640 51.82 x 16.26 935
020504 4 3 8 163.5 125 80 2.030 x 0.690 56.64 x 17.53 1173
020502 2 3 6 183.5 125 80 2.480 x 0.750 62.99 x 19.05 1538
020501 1 3 4 175.0 125 80 2.630 x 0.780 66.80 x 18.81 1817
020510 1/0 3 4 200.0 125 80 2.816 x 0.830 71.53 x 21.08 2121
020520 2/0 3 4 221.5 125 80 3.015 x 0.880 76.58 x 22.35 2366