2000V TC/VFD shielded power cable

P7391-SP
Legacy:
Product Type

Round Cables

Gauge Size

14 AWG - 500 MCM

Shield Type

Uncoated Copper Tape

Jacket

PVC - Polyvinyl Chloride

Voltage

2000V

Insulation

XLPE - Cross-Linked Polyethlene

Temperature

90°C Dry, 90°C

Description
TC/VFD SHIELDED POWER CABLE 3 CONDUCTOR 2000 VOLTS
Specifications
UL 44 1277 ASTM B3 & B8 Color Code Per ICEA S-58-679 Method 4 IEEE 384 (IEEE 1202/CSA FT4) Flame Test ICEA S-95-658(NEMA WC-70)Construction
Construction
Conductor: Class B stranded, uncoated annealed copper conforming to ASTM B-3 and B-8. Insulation: Each conductor is insulated with black Crosslinked Polyethylene (XLP) conforming to ICEA S-95-658/NEMA WC-70, Table 3-7 and UL Standard 44 for Type RHH/ RHW-2. Three symmetrical bare copper ground conductors. Cable Core: Each conductor is black and printed with its conductor number in accordance with ICEA Method 4. Ground Wires: Three Class B stranded, un-coated annealed copper conforming to ASTM B-3 and B-8.. Assembly: Individual conductors are bare annealed copper covered with a cross linked polyethylene (XLP) insulation. The conductors are cabled together with fillers and three bare ground wires, shielded with a un-coated 5 mil thick copper tape (50% Overlap) and covered with an overall flame retardant, moisture and sunlight resistant PVC jacket. Shield: A 5 mil un-coated copper tape is helically wrapped over the twisted assembly with a 50% (nominal) overlap. The shield shall be in contact with the ground wires. Outer Jacket: A black, flame retardant Polyvinyl Chloride (PVC) jacket meeting the requirements of UL Standard 1277 is applied. UL 44 1277 ASTM B3 & B8 Color Code Per ICEA S-58-679 Method 4 IEEE 384 (IEEE 1202/CSA FT4) Flame Test ICEA S-95-658(NEMA WC-70)Construction
Application
Type TC-VFD 2 kV power cable is used to supply power to submersible motors, or for connection to other power devices in industrial settings. Primary installations include cable trays, raceways and outdoor locations where supported by a messenger wire. Type TC-VFD is listed for direct burial or in underground ducts and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. This cable may be used in wet or dry locations at temperatures not to exceed 90°C.
FAQ
No FAQs available at this time.
ISO Logo

Excellence and Responsibility

Paige has earned ISO 9001:2015 certification for its factories in Columbus, NE and Silao, Mexico. We are dedicated to ensuring customer satisfaction and continual improvement, while embracing sustainability practices.

You can view our latest ISO Certificates here.