Scroll To Top

2000V Submersible Motor Lead – P7305-SP

Home   »   2000V Submersible Motor Lead – P7305-SP   »   2000V Submersible Motor Lead – P7305-SP

2000V Submersible Motor Lead – P7305-SP

Voltage

600/2000V

Insulation

EPR - Ethylene Propylene Rubber

Sizes

14 AWG – 1111 AWG SINGLE CONDUCTOR

Jacket

CPE - Chlorinated Polyethylene Rubber

Share it
Approvals
Portable Extra Flexible EPR/CPE
SUBMERSIBLE PUMP
EXTRA FLEXIBLE
MOTOR LEAD CABLE 600/2000 VOLTS

 Single conductor submersible pump cable and motor lead RHH/RHW-2/RW90.
Dual rated submersible Type DLO. Impact, Abrasion, Ozone, Sun, Weather, Heat, Oil, and Flame resistant.

Single conductor cable, designed for uses requiring flexible heavy duty power cables. For portable or fixed installations, leads for motors, generators, batteries, jumper cables or deep well submersible pump calbe. Dual rated Type DLO. Impact, Abrasion, Ozone, Sun, Weather, Heat, Oil, and Flame resistant.

  • UL listed RHH/RHW-2 600v & 2000v
  • Rated 2kV DLO, 1kV RW90
  • 90°C (dry), 90°C (wet)
  • Ozone, sunlight, oils, grease, weather, chemical and abrasion resistant jacket and chemicals.
  • Tray cable (TC) rated RW-90 CSA
  • MSHA, VW-1, SUN RES, FOR CT USE for sizes 1/0AWG and larger and for black jacket
  • Limited Smoke (LS) ST 1 in accordance with (UL) 1685

Nominal Voltage: RHH/RHW-2 600 and 2000V, R90 CSA, RW90 C9UL), 1kV, DLO 2kV.

Conductors: Annealed flexible stranded tin coated copper conductor in accordance with ASTM B-172, ASTM B-33.

Cable Reinforcement: Power conductors and cured rubber fillers cabled together. Single faced rubber filled binder tape applied over the assembly for mechanical protection.

Separator: A suitable tape separator between the conductor and insulation.

Insulation: Ethylene-propylene rubber (EPR) type EP, meeting UL, CSA and ICEA requirements for 90˚C

Jacket: A heavy duty, thermosetting CPE or CP compound in accordance with ICEA S-68-516 NEMA WC-8.

Color of Jacket: Black; Other colors available.

MSHA: P-7268080-01-MSHA (CPE)

UL: E193954 (CPE Jacket) RHW-2 90˚C Wet and Dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use.

C(UL): E19354: “(TYPE) RW90 EP”; “1000V”; “FT1”

CSA: 1101209 (LL103932): “205591” or  “103932”; RW-90 90˚C; “FT1”; “FT4”; “-40˚C”; “OIL RES” (CPE) TC (Tray Cable) SR (Sun Res) 1/0 and larger.

Paige Part # Power Conductor Size Power Conductor Stranding Conductor Diameter Nominal Insulation Thickness Nominal Jacket Thickness Maximum O.D. Approximate Weight Ampacity (1) 30°C Ambient Temp.
AWG or MCM No. of Stranding inches inches inches inches mm (lb/1000) kgs/km
DLO14 14 19/27 0.074 0.045 0.030 0.236 6.0 25 37 35
DLO12 12 19/25 0.094 0.045 0.030 0.256 6.5 46 68 40
DLO10 10 27/24 0.128 0.045 0.030 0.290 7.4 67 100 55
DLO8 8 37/24 0.147 0.060 0.030 0.333 8.5 95 141 80
DLO6 6 61/24 0.207 0.060 0.030 0.403 10.2 134 199 105
DLO4 4 105/24 0.264 0.060 0.030 0.461 11.7 192 286 140
DLO2 2 150/24 0.314 0.060 0.030 0.510 13.0 248 369 190
DLO1 1 225/24 0.390 0.080 0.045 0.650 16.5 428 637 220
DLO1/0 1/0 275/24 0.420 0.080 0.045 0.700 17.8 480 714 260
DLO2/0 2/0 325/24 0.460 0.080 0.045 0.740 18.8 558 830 300
DLO3/0 3/0 450/24 0.555 0.080 0.045 0.815 20.7 742 1104 350
DLO4/0 4/0 550/24 0.587 0.080 0.045 0.870 22.1 872 1298 405
DLO262 262 MCM 650/24 0.660 0.095 0.065 0.990 25.1 1068 1589 471
DLO313 313 MCM 775/24 0.725 0.095 0.065 1.055 26.8 1258 1872 511
DLO373 373 MCM 925/24 0.787 0.095 0.065 1.125 28.6 1462 2176 590
DLO444 444 MCM 1100/24 0.870 0.095 0.065 1.205 30.6 1726 2568 656
DLO535 535 MCM 1325/24 0.950 0.110 0.065 1.305 33.1 2047 3046 731
DLO646 646 MCM 1600/24 1.040 0.110 0.065 1.410 35.8 2416 3595 815
DLO777 777 MCM 1925/24 1.130 0.110 0.065 1.500 38.1 2881 4287 905
DLO929 929 MCM 2300/24 1.208 0.120 0.065 1.610 40.9 3455 5142 1005
DLO1111 1111 MCM 2750/24 1.370 0.125 0.095 1.800 45.7 4077 6067 1115
Ampacities (Amps per conductor) are based on 30°C ambient temperature in air. 90°C conductor temperature per the 2002NEC Table 310.17